| MINMAX產品-MINMAX模塊電源 1W, High Isolation SIP, Single & Dual Output DC/DC Converters |  | 
|  | 
| Key Features |  
| ‧ Efficiency up to 81% |  
| ‧ 3000VDC Isolation |  
| ‧ MTBF > 2,000,000 Hours |  
| ‧ Low Cost |  
| ‧ Input 5, 12 and 24VDC |  
| ‧ Output 3.3, 5, 9, 12, 15, ±5, ±9, ±12 and ±15VDC |  
| ‧ Temperature Performance -40°C to +85°C |  
| ‧ UL 94V-0 Package Material |  
| ‧ Internal SMD Construction |  
| ‧ Industry Standard Pinout |  | 
|  | 
| 
|  |  
| 
| Model Number | Input Voltage | Output Voltage | Output Current | Efficiency | Load Regulation |  
| VDC | VDC | mA | % Typ. | % Max. |  
| MAU201 |  | 3.3 | 260 | 73 | 10 |  
| MAU202 | 5 | 200 | 71 | 10 |  
| MAU203 | 9 | 110 | 76 | 8 |  
| MAU204 | 12 | 84 | 78 | 7 |  
| MAU205 | 15 | 67 | 78 | 7 |  
| MAU206 | ±5 | ±100 | 72 | 10 |  
| MAU207 | ±9 | ±56 | 77 | 8 |  
| MAU208 | ±12 | ±42 | 78 | 7 |  
| MAU209 | ±15 | ±34 | 79 | 7 |  
| MAU211 |  | 3.3 | 260 | 74 | 8 |  
| MAU212 | 5 | 200 | 73 | 8 |  
| MAU213 | 9 | 110 | 78 | 5 |  
| MAU214 | 12 | 84 | 80 | 5 |  
| MAU215 | 15 | 67 | 80 | 5 |  
| MAU216 | ±5 | ±100 | 74 | 8 |  
| MAU217 | ±9 | ±56 | 79 | 5 |  
| MAU218 | ±12 | ±42 | 81 | 5 |  
| MAU219 | ±15 | ±34 | 81 | 5 |  
| MAU221 |  | 3.3 | 260 | 73 | 8 |  
| MAU222 | 5 | 200 | 71 | 8 |  
| MAU223 | 9 | 110 | 76 | 5 |  
| MAU224 | 12 | 84 | 78 | 5 |  
| MAU225 | 15 | 67 | 79 | 5 |  
| MAU226 | ±5 | ±100 | 72 | 8 |  
| MAU227 | ±9 | ±56 | 76 | 5 |  
| MAU228 | ±12 | ±42 | 79 | 5 |  
| MAU229 | ±15 | ±34 | 80 | 5 |  |  
|  |  | 
|  | 
| 
| Minmax's MAU200 1W DC/DC's are specially designed to provide
 high levels of isolation 3000VDC
 in a miniature SIP package.
 The series consists of 27 modelswith input voltages of 5V, 12V and
 24VDC which offers standard output
 voltages of 3.3V, 5V, 9V, 12V, 15V,
 ±5V, ±9V, ±12V and ±15VDC for a
 wide choice.
 The MAU200 series is an excellentselection for a variety of applications
 including distributed power systems,
 mixed analog/digital subsystems,
 portable test equipments, local power
 networks and battery backed systems.
 
   | Mechanical Dimensions | 
| Pin Connections |  
|  |  
| Pin | Singles | Duals |  
| 1 | +Vin | +Vin |  
| 2 | -Vin | -Vin |  
| 5 | -Vout | -Vout |  
| 6 | No Pin | Common |  
| 7 | +Vout | +Vout |  
| Case Size – |  
| 5V & 12V Input – 19.5x6.1x10.2mm |  
|  | (0.77x0.24x0.40inch) |  
| 24V Input –19.5x7.1x10.2mm |  
|  | (0.77x0.28x0.40inch) |  
| Case Material – |  
| Non-Conductive Black Plastic |  
| Weight – |  
| 5V & 12V Input – 2.2g (0.08Oz) |  
| 24V Input– 2.6g (0.09Oz) |  
| Tolerance | Millimeters | Inches |  
|  | X.X±0.25 | X.XX±0.01 |  
|  | X.XX±0.13 | X.XXX±0.005 |  
| Pin | ±0.05 | ±0.002 |  
|  |  |  
|  |  
|  |  
|  |  | 
|  | 
| 
| 
Exceeding the unit absolute maximum ratings could cause damage. These are not continuous operating ratings.
| Absolute Maximum Ratings |  
| Parameter | Min. | Max | Units |  
| Input Surge Voltage (1000mS) | 5VDC Input Models | -0.7 | 9 | VDC |  
| 12VDC Input Models | -0.7 | 18 | VDC |  
| 24VDC Input Models | -0.7 | 30 | VDC |  
| 
Lead Temperature(1.5mm from case for 10sec.)
 | --- | 260 | °C |  
| Internal Power Dissipation | --- | 450 | mW |  |  | 
| General Characteristics |  
| Parameter | Conditions | Min. | Typ. | Max. | Units |  
| Isolation Voltage | 60 Seconds | 3000 | --- | --- | VDC |  
| Isolation Resistance | 500VDC | 10 | --- | --- | GΩ |  
| Isolation Capacitance | 100kHz, 1V | --- | 60 | 100 | pF |  
| Switching Frequency |  | 70 | 100 | 120 | kHz |  
| MTBF | MIL-HDBK-217F @25°C Ground Benign | 2 | --- | --- | MHrs |  |  | 
|  | 
| 
| 
| Environmental Characteristics |  
| Parameter | Conditions | Min. | Max. | Units |  
| Operating Temperature | Ambient | -40 | +85 | °C |  
| Operating Temperature | Case | -40 | +90 | °C |  
| Storage Temperature |  | -40 | +125 | °C |  
| Humidity |  | --- | 95 | % |  
| Cooling | Free-Air Convection |  |  | 
| Output Characteristics |  
| Parameter | Conditions | Min. | Typ. | Max | Units |  
| Line Regulation |  | --- | ±1.2 | ±1.5 | % |  
| Load Regulation | Io = 20% to 100% | See Selection Guide | % |  
| Ripple & Noise 
 | 20MHz BW | --- | 65 | 100 | mV P-P |  
| Short Circuit | 0.5 Second Max. |  |  
|  |  
|  | 
| Maximum Capacitive Load |  
| Models by Output Voltage(Each Output on Duals)
 | Singles | Duals | Units |  
| 220 | 100 | uF |  |  
|  |  | 
|  | 
| 
| 
| Derating Curve (3.3, 5 & ±5V Outputs) |  
|  |  |  |  |  
| 
| 1. | Specifications typical at Ta=+25°C, resistive load, nominal input voltage, rated output current unless otherwise noted. |  
| 2. | These power converters require a minimum output load to maintain specified regulation. |  
| 3. | Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. |  
| 4. | All DC/DC converters should be externally fused at the front end for protection. |  
| 5. | Other input and output voltage may be available, please contact factory |  
| 6. | All specifications subject to change without notice. |  
|  |  |  |  
|  |  
| 
| Derating Curve (Other Outputs) |  
|  |  |  |  |  |